Sunday, January 18, 2009
Recovering after a flood
Crawlspaces:
Friday, December 26, 2008
Home energy savings tips
1A attic access door
2. In finished attic rooms with or without dormer,
insulate …
2A between the studs of "knee" walls;
2B between the studs and rafters of exterior walls and roof;
2C ceilings with cold spaces above;
2D extend insulation into joist space to reduce air flows.
3. All exterior walls, including …
3A walls between living spaces and unheated garages, shed roofs, or storage areas;
3B foundation walls above ground level;
3C foundation walls in heated basements, full wall either interior or exterior.
4. Floors above cold spaces, such as vented craw spaces and unheated garages. Also insulate …
4A any portion of the floor in a room that is cantilevered beyond the exterior wall below;
4B slab floors built directly on the ground;
4C as an alternative to floor insulation, foundation walls of un-vented crawl spaces;
4D extend insulation into joist space to reduce air flows.
5. Band joists.
6. Replacement or storm windows and caulk and seal around all windows and doors.
Monday, December 1, 2008
Outdoor electrical safety tips for holiday lighting
Use care not to overload your circuits. Do not run too many strings together, the amount of lights on string that can safely be connected differs for each type of light. Read and follow the manufacturer's recommendations. Carefully inspect each string for frayed insulation, loose connections or broken bulbs. Never plug in a string that has bulbs broken open, as the interior filament is a electrocution hazard. Only use lights outdoors that are approved for outdoor use.
Use timers to control your lighting to save more energy. This chart dramatically contrasts the old style bulbs with modern LCD technology lighting using as little as 1.15% of the energy of the old style lighting.
Another consideration is heat. Never install old style bulbs on a real tree. Think of string of 100, 10 watt lights, that is 1000 watts light and heat. You would never put a 1000 watt heater on a tree for obvious reasons, and these strings are nearly the equivalent of doing just that.
Be careful when hanging lights. Loose wiring is more easily damaged by movement from trees and wind. Never use standard staples, as they can cut into insulation and cause a short or shock hazard. Best to use insulated clips to hang lighting.
GFCI protected outlets are recommended for all outdoor electrical use. They dramatically reduce the risk of electrical shocks and electrocutions.
Use only UL approved exterior grade power cords outside with proper ground (3 prong connector). Never run cords through doorways, windows where they could get damaged or be a trip hazard. Keep all plugs and connectors off the ground, away from puddles and snow.
If you blow fuses or trip breakers, reduce the load on that circuit. Never change the amperage if a blown fuse, if a 15 amp fuse blows, reduce the load on that circuit and replace with the exact same type 15 amp fuse. The wiring in the home is designed to only carry the current of the fuse. That blown fuse likely prevented the wiring from overheating and possible fire.
If you see flickering lights, sparks, warm switches, plugs, or outlets, or dimming lights, there is a potential dangerous problem that could cause an electrical fire.
As always use extreme care on ladders, make sure they have a good footing and are steady. Never touch your exterior power drop! Any contact with a poorly insulated drop will kill you, an aluminum ladder is an excellent electrical conductor.
Read more about holiday lighting safety here from Washington State University Extension Energy Program and the Northwest Energy Efficiency Alliance.
If you find this information useful, don't keep us a secret! List us on any of your favorite networking / bookmarking sites
Tuesday, October 28, 2008
Getting Your Home Ready For Winter
If you have an oil furnace, have it checked annually. A very small adjustment can make a huge difference in your heating bill, not to mention reducing the pollution from poorly adjusted burners. By the way, with oil prices at unusually low prices, it might be a good time to fill up the tank before these prices go back up.
Gas furnaces should be checked regularly too. Our recommendations is to have the 1st service at 5 years, again at 10, then every year thereafter. Be sure to keep up on changing your furnace filters. If you have a electric fan forced wall unit (like a cadet) be sure to properly clean them. We have a copy of the instructions here.
Chimneys, If you heat with wood, have your flue swept and checked every year. Examine wood stoves for cracked or missing fire bricks, poor door seals, and loose or damaged flue pipes. All non frost free hose bibs should be insulated to protect them from freezing. Be sure to disconnect hoses! A hose will cause a frost free hose bib to freeze when the water in the hose freezes.
Clean gutters and check the downspouts assuring that they discharge away from the building, the further the better
Look at all trees, and other plants. They should be trimmed back so they cant touch the home. Any contact is a natural path for insects, rodents, and can contribute to structural pests.
Walk around your home and look at the bottom row of siding. Ideally there should be 6 inches of concrete below the bottom row of siding. If soil or bark is piled too high there is a much greater chance of problems with termites ants or beetles damaging the home.
Look at every window and door. Check weather stripping, repair as necessary. Look at every threshold and door sweep, if there are gaps, you will be loosing heat. Caulk all gaps in siding, trim, utility holes, etc.
If it is safe to do so, remove any leaves and other debris from the roof. Use great care to not remove the granules on a aspalt roof. (DO NOT PRESSURE WASH) Ideally on a dry day, carefully use a leaf blower, debris in valleys and behind chimney's can cause water to back up and cause leaks.
Check your smoke detectors. If you have an attached garage, live in multi-family, or have gas, oil or wood burning appliances, you must have a carbon monoxide detector!! All homes should have them, since there is no way to tell if you have a problem with CO. Most people never know they have a problem untill someone is make sick or they are killed. Take any warning from a carbon monoxide detector very seriously, and call the fire department.
If you find this information useful, don't keep us a secret! List us on any of your favorite networking / bookmarking sites
Monday, July 14, 2008
Is your deck safe?
There have been 800 injuries and 20 deaths in the last 10 years directly connected to unsafe decks and collapses. We are not only trained home inspectors, but as builders of decks, we understand the importance of proper deck construction.
We see substandard decks all the time, with dangerous railings, improper attachments, missing joist hangers and poorly built stairs. Safety rails on decks should be 36" high and have no openings greater then 4". The building codes for these rails have changes dramatically over the years. When I first started building decks, the pickets could be spaced up to 9" apart. This can pose a significant hazard for children, so older decks should be retrofitted with proper railings. All handrails along stair cases should between 30" and 34" above the stair nose and on at least one side of the side of close stair openings or both sides of open stairs.
The today show did a report on deck safety. See the video here
Make sure you deck is thoroughly inspected, your life may depend on it!
If you find this information useful, don't keep us a secret! List us on any of your favorite networking / bookmarking sites
Friday, June 20, 2008
Window Fall Hazards
Tuesday, March 25, 2008
Attic Ventilation
Why are vents important?
All homes should have attic ventilation, but most do not have enough. The temperature in the attic should be close to the outside air temperature but almost never is. I have personally recorded up to 145 degrees on a sunny summer day. Inadequate vents will contribute to wood decay, break down roofing prematurely, and will often lead to bio-growth (mold, mildew and fungus) Bio-growth over time may cause significant structural damage and potential health problems. If you look at a modern home, there are lots of roof vents. Modern building codes call for 1 square foot of ventilation for every 150 to 300 square feet of attic floor space, depending on vapor barrier and other construction factors. That means for a typical 1500 sq foot home, there should be 5 to 10 square feet of ventilation. Almost no older homes have this and therefore their attics are hot, humid and are a ready breeding ground for bio-growth and structural pests.
Adding Vents
We are continually recommending better ventilation in attics, and if you are re-roofing a home, it is usually a good idea to add several. They are cheap, and easy to install when re roofing, and will make the roofing and framing last longer. Roofers will sometimes complain at the time because they often don't want to stop the roofing project long enough to cut new holes in the roof but insist on them anyway. As with all contractors, time is money and to set up a saw, cut the hole and properly weave in the vent takes a few minutes more. It is worth every penny!
Powered vent options
One excellent idea to add better ventilation for you attic is to consider a powered vent. Electric vents can move a lot more air and moisture from your home then passive ventilation. These come in several types, and most require professional installation. All powered vents will help reduce excess heat in the summer, potentially saving money in AC bills and making the home more comfortable. One of the newer and exciting energy saving alternatives are the solar powered vents. These have the advantages of the powered vents, but require no electricity from the home to run, and therefore no electrical permits to install. They can be thermostatically controlled, and will run when ever the sun is shinning. They are more expensive but since they use no power from the home, can be easier to install and they save electricity too. Read more about solar powered vent options here.
If you find this information useful, don't keep us a secret! List us on any of your favorite networking / bookmarking sites